Description

Precise, High-Speed Measurements

  • Linearity: 0.2%
  • Typical Resolution (see Probe and Range below for specifics):
    • Nonferrous: 15 kHz – 0.007%; 100 Hz – 0.002%
    • Ferrous: 15 kHz – 0.009%; 100 Hz – 0.003%
  • Bandwidth: to 15 kHz

Convenient Output Interface and Range Selections

  • Ranges from 0.25 mm to 15 mm
  • Industry standard 0-10 VDC Output
  • Setpoint Contacts Output
  • CE Complilant

Versatile, Useful Features

  • Probe can be used in wet, dirty environments
  • Push-Button Offset
  • Push-Button Switch Threshold (Setpoint)
  • Range Indicating LEDs
  • Remote Offset and Threshold Activation
  • User-Selectable Bandwidth/Resolution
    100 Hz, 1 kHz, 10 kHz, 15 kHz (not available on ‘e’ version)
  • Probes can be ordered as vacuum compatible.

Life-Cycle Status: Active

Export Requirements

Because of high resolutions, exports of the ECL202 may require an export license.

ECL202e

The ECL202e has different resolution specifications, no bandwidth selection, and can ship without an export license.

Probes, Ranges, and Resolutions (Probe Dependent)

Listed specifications assume a 3 meter probe cable; flat measurement area diameter at least 3 times larger than the probe diameter; and no customizations.

Probes can be ordered as vacuum compatible; custom probes are available.

Standard and Fine Ranges, Resolutions, Thermal Drift

Listed specifications are for standard target materials: Nonferrous = Al 6160, Ferrous = 4140 Steel.

Specifications

Typical specifications for standard targets and probes. Actual values depend on probe, target, and calibration. Specifications assume a target area at least three times the diameter of the probe.

Resolution:
RMS, TypicalDependent on probe and range.
See Range Table for resolution specifics.
ECL202 Nonferrous: 15 kHz – 0.007%

100 Hz – 0.002%

Ferrous: 15 kHz – 0.009%

100 Hz – 0.003%

ECL202e See Range Table table below
Linearity 0.2% of Range
Error Band 0.4% of Range
Bandwidth

 

ECL202: Selectable: 100 Hz, 1 kHz, 10 kHz, 15 kHz

ECL202e: 15 kHz

Driver Temperature Drift
(15°C-50°C)Typical. See Range Table chart for details.
0.01% F.S./°C
Probe Temperature Drift
(15°C-65°C, except where noted)Typical. See Range Table chart for details.
0.01% F.S./°C
Analog Output 0-10 VDC, 0 Ω, 15 mA
Switched Output 30 VAC/60 VDC/100 mA
Input Power 15-24 VDC

2.5  W

Driver Operating Environment 4°C-50°C

IP40

Probe Operating Environment

Standard Probes come with PUR (Polyurethane) jacketed cables. High Temperature Probes have FEP jackets.

Other temperature ranges may be possible. Contact us for more information.

Standard Probes: IP67

High Temperature Probes: IP63

U3 Probe Standard Probe (PUR Cable):
-25°C to +125°C
(Available with optional FEP cable)High Temperature Version Not Available
U5-18 Probes Standard Probes:
-25°C to +125°CHigh Temperature Probes:
-25°C to +200°C
U25-50 Probes Standard Probes:
-25°C to +125°CHigh Temperature Probes:
-25°C to +175°C

 

 

 

 

eddy-current probeeddy-current probe cal

noise image

Integral filters included in the ECL202

Probe

probe flyout

Measurement Range

Target
Type

Resolution* @ Bandwidth

Thermal Drift**

%F.S./°C

Range Type

Range

mm
inch

Near Gap

mm
inch

ECL202

ECL202e

100 Hz
µm
µinch
1 kHz
µm
µinch
10 kHz
µm
µinch
15 kHz
µm
µinch
15 kHz
µm
µinch
Probe Driver

U3

eddy-current probe

Fine 0.25
0.010
0.05
0.002
nonferrous 0.010
0.4
0.015
0.6
0.025
1.0
0.030
1.2
0.04 0.04
ferrous 0.015
0.6
0.025
1.0
0.040
1.6
0.050
2.0
0.06 0.10
Standard 0.50
0.020
0.05
0.002
nonferrous 0.025
1.0
0.030
1.2
0.060
2.4
0.065
2.6
0.400
16
0.04 0.04
ferrous 0.030
1.2
0.040
1.6
0.100
4.0
0.110
4.4
0.400
16
0.08 0.08

U5

eddy-current probe

Fine 0.625
0.025
0.25
0.010
nonferrous 0.030
1.2
0.035
1.4
0.070
2.8
0.075
3.0
0.04 0.04
ferrous 0.040
1.6
0.050
2.0
0.075
3.0
0.080
3.2
0.08 0.04
Standard 1.25
0.050
0.25
0.010
nonferrous 0.045
1.8
0.065
2.6
0.140
5.6
0.150
6.0
0.400
16
0.04 0.10
ferrous 0.080
3.2
0.120
4.8
0.240
9.6
0.260
10.4
0.400
16
0.10 0.10

U8

eddy-current probe

Fine 1.0
0.040
0.35
0.015
nonferrous 0.020
0.8
0.030
1.2
0.050
2.0
0.060
2.4
0.02 0.04
ferrous 0.050
2.0
0.060
2.4
0.100
4.0
0.110
4.3
0.04 0.04
Standard 2.00
0.080
0.35
0.015
nonferrous 0.040
1.6
0.060
2.4
0.135
5.4
0.145
5.8
0.400
16
0.02 0.04
ferrous 0.070
2.8
0.080
3.2
0.180
7.2
0.200
8.0
0.400
16
0.04 0.04

U12

eddy-current probe

Fine 1.6
0.065
0.60
0.025
nonferrous 0.040
1.6
0.050
2.0
0.100
4.0
0.110
4.4
0.01 0.01
ferrous 0.050
2.0
0.070
2.8
0.120
4.8
0.130
5.1
0.02 0.02
Standard 3.50
0.140
0.60
0.025
nonferrous 0.060
2.4
0.090
3.6
0.210
8.4
0.240
9.6
0.400
16
0.02 0.01
ferrous 0.100
4.0
0.170
6.8
0.250
10
0.300
12
0.400
16
0.03 0.01

U18

eddy-current probe

Standard 5.00
0.200
0.75
0.030
nonferrous 0.080
3.2
0.130
5.2
0.300
12
0.340
14
0.400
16
0.01 0.01
ferrous 0.130
5.2
0.200
8.0
0.390
16
0.450
18
0.500
20
0.01 0.01

U25

eddy-current probe

Standard 8.00
0.320
1.25
0.050
nonferrous 0.180
7.2
0.250
10
0.500
20
0.600
24
0.600
24
0.01 0.01
ferrous 0.180
7.2
0.250
10
0.500
20
0.600
24
0.600
24
0.01 0.01

U38

eddy-current probe

Standard 12.5
0.500
1.50
0.060
nonferrous 0.200
8.0
0.350
14
0.700
28
0.800
32
0.800
32
0.01 0.01
ferrous 0.200
8.0
0.350
14
0.700
28
0.800
32
0.800
32
0.02 0.01

U50

eddy-current probe

Standard 15.0
0.600
2.00
0.080
nonferrous 0.300
12
0.400
16
0.800
32
0.900
36
0.900
36
0.01 0.01
ferrous 0.300
12
0.450
18
0.900
36
1.00
40
1.000
40
0.01 0.01

* RMS values listed. Peak-to-Peak values are approximately 8-10 times RMS values. Read Understanding Sensor Resolution Specifications and Effects on Performance about this often misunderstood specification.
In high EMI environments, output noise may rise to 0.030VRMS (0.3% resolution)
** Thermal Drift specified at: Probe: 15°C-65°C; Driver: 15°C-50°C

 

Mechanical

ecl202 mechanical drawing