page contents

CPA100 and CPA100e

Capacitive Sensor:
CPA100 and CPA100e
Precision Analog Proximity Switch

Lower cost capacitive displacement sensor with adjustable Gain and Zero and setpoint switch output.

CPA100 Documents For Downloads:

Label Sensor Manual EnglishUser Manual

clear label sensor catalogCapacitive Sensor Catalog

label sensor CE documentCE Declaration of Conformity

Description

High-Speed Analog Output for Linear Position Monitoring

  • 0-10 V Output
  • 15 kHz Bandwidth
  • Resolution: CPA100: 0.03% RMS @ 15 kHz @ mid-range
  • Resolution: CPA100e: 0.3 µm RMS or higher @ 15 kHz @ mid-range

High-Repeatability Proximity Switched Output

  • Setpoint/Switched Output (Switch Closure)
  • Adjustable Gain and Zero/Switch-Point
  • Repeatability as low as 1 micron

Configurable for Your Application

  • Ranges Available: 50 µm – 12.5 mm
  • External Gain and Zero adjustment connections
  • DIN Rail Case
  • Multiple Channel Sync (requires sync cable kit)
  • Standard Probes can be ordered as vacuum compatible.

Life-Cycle Status: Active

Export Requirements

Because of high resolutions, exports of the CPA100 may require an export license.

CPA100e

The CPA100e has different resolution specifications and can ship without export license delays.

Proximity Sensors and Displacement Sensors

Proximity sensors are often used for simple presence/absence detection – this is why they are often called proximity “switches.” But some applications require higher performance measurement. Applications where the difference between present and absent may only be a few microns require higher resolution sensors than a typical proximity switch. The CPA100 can resolve a target’s position to less than 50 microns and do so at up to 15 kHz. It also provides a nonlinear analog output to provide feedback proportional to the target’s position.

Applications

Production Line Part Sorting

Double Sheet Detection (paper or other nonconductors)

Assembly Process Monitoring: Position, Level, Squareness

Specifications

Typical specifications. Actual values depend on probe and calibration.

Resolution

@ mid-range

@ 15 kHz

(Typical)

CPA100: 0.03%F.S. RMS

CPA100e: 0.3 µm RMS or higher

Details on Probes and Ranges

Bandwidth 15 kHz (-3dB)
Linearity Nonlinear (see chart below)
Maximum Drift Driver: 0.2% F.S./°C

Probe: 0.05% F.S./°C

Analog Output 0-10 VDC, 0 ohms, 15 mA max
Setpoint Output Solid state switch closure: 30 VAC/60 VDC max

On state: 2.5 Ω, 100mA max Off state leakage: 10µA max

Analog Output Impedance 0 ohms
Operating Temperature 4°C-50°C
Input Power 15-24 VDC, 2.5 W

CPA100 Ranges/Resolutions – Probe Dependent

Listed specifications assume a 2 meter probe cable; flat measurement area diameter at least 1.3 times larger than the Sensing Area diameter; and no customizations.

1 mil = 0.001″

probe-sensor cal Noise image

Standard Probes

Sensing Area
Diameter

mm

Measurement Range

Resolution* @ 15 kHz

Body Style

capacitive sensor probe dimensions

Range
Type
Range
µm
mils
Near Gap
µm
mils
CPA100
nm
µin
CPA100e
nm
µin
0.5 Standard 50
2.0
50
2.0
55
2.5
400
16

Extended 80
3.0
60
2.4
100
4.0
400
16
0.8 Standard 100
4.0
100
4.0
55
2.5
400
16

2.0 Standard 250
10.0
125
5.0
40
1.6
400
16

Extended 500
20.0
125
5.0
55
2.5
400
16
3.2 Standard 500
20.0
250
10.0
85
3.5
400
16
Extended 1250
50.0
250
10.0
130
5.0
400
16
5.6 Standard 500
20.0
500
20.0
140
5.5
400
16

20mm rectangular probe

Extended 2000
90.0
250
10.0
170
7.0
800
32
13 Standard 3200
125
2000
80
1000
40
1000
40
Extended 5000
200
3000
120
1600
63
1600
63
19 Standard 2500
100.0
5000
200
800
30
800
30
Extended 6000
250.0
3000
120
1100
43
1100
43
21 Standard 8000
300
5000
200
1200
47
1200
47
Extended 12500
500
5000
200
1600
63
1600
63

* Resolution is RMS value at midrange. P-P resolution is 8-10 times higher.

Typical Linearity for Standard and Extended Range Calibrations

cpa100 capacitive sensor linearity

Mechanical Details